Development of a cooling channel optimization framework using Moving Morphable Components (MMC)

Development of a cooling channel optimization framework using Moving Morphable Components (MMC)Development of a Framework for Optimizing Cooling Channels Using Moving Morphable Components (MMC)

A co-authored paper on a method for optimizing the topology of cooling channels, written by our employees Hirotani, Shintani, and Furusawa, and Associate Professor Kentaro Yachi of the Graduate School of Engineering, Osaka University, has been published in an international academic journal.Structural and Multidisciplinary OptimizationIt was accepted by (SMO) [1]. In this article, I would like to explain the content and ideas of the paper as clearly as possible.

Introduction

Topology optimization can provide design insights that humans might not have considered, and is an effective method for designing better products.[2]

Among topology optimization methods, density-based topology optimization is widely used and applied to many fields, including not only structural engineering but also thermal fluid dynamics.[3]

fillet


Example of applying density method-based topology optimization to cooling channels

However, optimization results often involve complex shapes, leaving challenges in physical interpretation, implementation in manufacturing, and quality control.

While it is possible to indirectly control component dimensions using filters in topology optimization based on density methods, it is difficult to accurately reflect complex design constraints in the optimization results.

To obtain practical design solutions based on existing manufacturing technologies, post-processing is required in which the designer interprets the optimization results and adjusts them into a manufacturable shape while taking meticulous care not to compromise their optimality.

Furthermore, when converting the optimization results into a CAD model, post-processing is essential to convert the density image, which includes grayscale, into a clear CAD model.

In this study, we proposed a topology optimization method for cooling channels that allows for flexible incorporation of geometric design constraints such as dimensions, facilitates interpretation of the physical meaning of the resulting shape, and easily leads to shape adjustments after optimization.

Moving Morphable Components (MMC)

One topology optimization technique is Moving Morphable Components (MMC) [4].

fillet


Conceptual diagram of Moving Morphable Components (MMC)

Moving Morphable Components (MMC) is a method that, separate from the finite elements used in the analysis, places elements that can potentially form members with optimal geometric shapes as "constituent elements" in the design domain beforehand, and then represents geometric shapes by moving, rotating, scaling, and superimposing these constituent elements.

For an overview of the MMC formulation and its application to structural benchmark problems, please refer to previous articles.

Overview and comparison of topology optimization methods | Nature Architects inc.

In MMC, shape information such as the dimensions, position, and angle of components can be directly controlled as design variables.

  • "The thickness of this component will be limited to a specific range."
  • "This component should only be movable within the specified area."
  • "These adjacent components maintain C¹ continuity.[5]"

It is possible to strictly incorporate geometric constraints such as those mentioned above into the optimization process.

Furthermore, because the design variables are the shape parameters themselves, it offers the practical advantage of seamlessly transferring optimization results to a CAD system.

Outline of the proposed cooling channel optimization framework

In this study, we defined components assigned different physical roles: "walls" that form global flow paths and "fins" that promote local heat transfer. By dividing the optimization process according to each role, we proposed a two-stage optimization method that suppresses competition between the two. A conceptual diagram of the method is shown below.

fillet


Conceptual diagram of the proposed two-stage optimization method

    Step 1 : Place wall components and fin components within the design area.

    Step 2 Optimize the global flow path network using only wall components as design variables.

    Step 3 : Remove any wall components after optimization whose dimensions fall below a predetermined threshold and do not contribute to the formation of global flow paths.

    Step 4 : Remove fin components located closer than a predetermined threshold distance to the remaining wall components, leaving only the fin candidates to be used in the second stage of optimization.

    Step 5 : Optimize the local heat transfer characteristics within the flow path by using only the remaining fin components as design variables.

    Step 6 Finally, remove any fin components whose dimensions fall below a predetermined threshold, and adopt the resulting structure as the final design.

The specific optimization process is as described in Steps 1 through 6 above.

By dividing the optimization process into stages according to the physical role of each component, and pruning components that do not conform to the intended purpose between these stages, it becomes possible to obtain a result that aligns with the design intent and facilitates manufacturing.

Thermal fluid analysis model

This study employs a two-layer thermal fluid model consisting of an upper thermal fluid layer containing a cooling fluid and channel walls, and a lower substrate layer that receives heat from a heat-generating element [6].

Originally, the three-dimensional flow and heat transfer are reduced to a two-dimensional problem by assuming velocity and temperature distributions in the thickness direction, thereby efficiently performing the numerous analyses required for topology optimization.

In the upper thermal fluid layer, we assume an incompressible fluid flow and solve the continuity equation.

\[ \nabla \cdot \mathbf{u}=0 \]

here, \(\mathbf{u}\)This represents the flow velocity in the in-plane direction.

The momentum conservation law uses the following equation, which includes the Brinkman resistance that suppresses flow within the solid region.

\[ \frac{6}{7}\rho\left(\mathbf{u}\cdot\nabla\right)\mathbf{u}=-\nabla p+\mu\nabla\cdot\left[\nabla\mathbf{u}+\left(\nabla\mathbf{u}\right)^{\mathrm{T}}\right]-\alpha(\gamma)\mathbf{u} \]

Last on the right side \(-\alpha(\gamma)\mathbf{u}\)This is a Brinkman resistor.

By reducing resistance in the fluid domain and increasing resistance in the solid domain, the flow path and walls are represented within the same equation.

Temperature of the upper thermal fluid layer\(T_t\)This involves considering heat transport by flow, heat conduction in the in-plane direction, and heat exchange with the lower substrate layer.

\[ \frac{2}{3}\rho C_p\mathbf{u}\cdot\nabla T_t-\frac{49}{52}\nabla\cdot\left(k_t(\gamma)\nabla T_t\right)-\frac{h(\gamma)}{2H_t}\left(T_b-T_t\right)=0 \]

The first term represents heat advection by the fluid, the second term represents heat conduction, and the third term represents heat transfer between the upper thermal fluid layer and the lower substrate layer.

In the lower substrate layer, without considering airflow, the heat conduction within the substrate is calculated using the following formula.

\[ -\frac{k_b}{2}\nabla^2 T_b+\frac{h(\gamma)}{2H_b}\left(T_b-T_t\right)-\frac{q_0^{\prime\prime}}{2H_b}=0 \]

here, \(T_b\)This is the typical temperature of the substrate layer.\(q_0^{\prime\prime}\) This is the heat flux supplied by the heat source.

The heat transferred from the heating element to the substrate is conducted through the substrate and then moves to the fluid or channel wall above.

Mathematical representation of MMC components and their reflection in physical properties

In MMC, walls and fins are represented as geometrically explicit components, and their position, dimensions, and angles are used as design variables. On the other hand, in thermal fluid analysis, it is determined whether each position on a fixed finite element mesh is a fluid or a solid, based on the material distribution. \ (\ gamma \) It needs to be expressed by [this method].

Therefore, in this study, the shape of the MMC components is reflected in the material properties of the thermal fluid analysis in the following manner.

\[ \text{Design variables for MMC components}\rightarrow\text{Topology Description Function (TDF)}\rightarrow\text{Projected TDF}\rightarrow\gamma\rightarrow\left\{\alpha(\gamma),\ k_t(\gamma),\ h(\gamma)\right\} \]

here, \(\alpha(\gamma)\)fluid resistance,\(k_t(\gamma)\) The effective thermal conductivity of the upper thermal fluid layer is\(h(\gamma)\) This is the heat transfer coefficient between the upper and lower layers.

TDF of wall components

Any point within the design domain \((X,Y)\)The center coordinates of the wall components \((X_0,Y_0)\) Let's assume that. First, we define the local coordinates aligned with the orientation of the wall components as follows:

\[ \Delta X_w=X-X_0,\qquad \Delta Y_w=Y-Y_0 \]
\[ s_w=\Delta X_w\cos\theta+\Delta Y_w\sin\theta \]
\[ n_w=\Delta X_w\sin\theta+\Delta Y_w\cos\theta \]

here, \(s_w\) The wall runs along its length.\(n_w\) These are local coordinates in a direction perpendicular to the longitudinal direction,\(\theta\) This is the rotation angle of the wall component.

The shape of the wall components is represented by a 6th-order hyperelliptic TDF.

\[ \phi_w(X,Y)=1-\left(\frac{s_w}{L}\right)^6\left(\frac{n_w}{t}\right)^6 \]

here, \(L\)This is the lengthwise dimension.\(t\)This is the width dimension.

By setting the exponent to 6, the bar-shaped wall, which is closer to a rectangle than a normal ellipse, is represented as a smooth function.

TDF of fin components

Similarly, for the fin components, their central coordinates are \((X_f,Y_f)\)We define local coordinates as follows.

\[ \Delta X_f=X-X_f,\qquad \Delta Y_f=Y-Y_f \]
\[ s_f=\Delta X_f\cos\psi+\Delta Y_f\sin\psi \]
\[ n_f=\Delta X_f\sin\psi+\Delta Y_f\cos\psi \]

here, \(\psi\)This is the fin's rotation angle.

The elliptical fin component is represented by the following TDF:

\[ \phi_f(X,Y)=1-\left(\frac{s_f}{a}\right)^2\left(\frac{n_f}{ka}\right)^2 \]

\(The\)The semi-major axis of the ellipse is\(to\)This is the ratio of the semi-minor axis to the semi-major axis, and the semi-minor axis \(B\)The equation is as follows:

\[ b=ka \]

Therefore,\(k=1\)In that case, it will be circular.\(to\)Making it smaller results in a long, narrow oval shape.

Furthermore, here \(to\)This is the axial ratio of the fin shape, and the thermal conductivity will be discussed later. \(k_f\),\(k_s\)It is different.

For both the wall and the fin, the TDF takes the following sign:

\[ \phi>0\quad\text{:Inside of the component} \]
\[ \phi=0\quad\text{:boundary of constituent elements} \]
\[ \phi<0\quad\text{:Outside of the constituent element} \]

Conversion from TDF to material distribution

Since TDF cannot be used directly as a material distribution between 0 and 1, we project each TDF onto a range of approximately 0 to 1 using a hyperbolic tangent function.

The projected TDF of the wall component is,

\[ \widetilde{\phi}_w(X,Y)=\frac{1}{2}\left[1-\tanh\left(\beta\phi_w(X,Y)\right)\right] \]

The projected TDF of the fin components is,

\[ \widetilde{\phi}_f(X,Y)=\frac{1}{2}\left[1-\tanh\left(\beta\phi_f(X,Y)\right)\right] \]

It is represented by:

\(\beta\)This parameter adjusts the sharpness of the transition between fluid and solid states at the boundaries of the constituent elements. In this definition, the projected TDF approaches 0 inside the constituent elements and approaches 1 outside the constituent elements.

\[ \text{Inside component:}\phi>0\Longrightarrow\widetilde{\phi}\simeq0 \]
\[ \text{External component:}\phi<0\Longrightarrow\widetilde{\phi}\simeq1 \]

Instead of directly multiplying the raw TDF of the wall and fins, the material distribution is calculated from the product of functions projected from 0 to 1. \ (\ gamma \)

Integrated material distribution of walls and fins

A collection of wall components \(C_w\), a set of fin components \(C_f\)Therefore, the material distribution across the entire design area can be expressed by the following equation:

\[ \gamma(X,Y;\mathbf{d})=\left[\prod_{m\in C_w}\widetilde{\phi}_{w,m}(X,Y;\mathbf{d}_{w,m})\right]\left[\prod_{n\in C_f}\widetilde{\phi}_{f,n}(X,Y;\mathbf{d}_{f,n})\right] \]

here, \(\mathbf{d}_{w,m}\) with \(\mathbf{d}_{f,n}\) These are the design variables for the wall component and the fin component, respectively.

The definition of material distribution in this study is:

\[ 0\leq\gamma\leq1 \]
\[ \gamma\simeq0\quad\text{:solid region} \]
\[ \gamma\simeq1\quad\text{:Fluid region} \]

.

Because we are taking the product of projected TDFs, if a point lies inside either a wall or a fin, then the position of that point is...\ (\ gamma \)The value approaches 0, and it is treated as a solid.

On the other hand, at points outside of all components, each projected TDF approaches 1,\ (\ gamma \)It approaches 1 and is treated as a fluid.

Therefore, this product represents the union of solid regions of multiple wall and fin components. Even when walls and fins overlap, that region is still solid.

In two-stage optimization, only the design variables being updated are switched; the representation of the material distribution itself remains the same in both the first and second stages.

Conversion from material distribution to fluid resistance

material distribution \ (\ gamma \)First, the Brinkman drag coefficient \(\alpha(\gamma)\)This is reflected in the following. The resistance between the fluid and the solid is interpolated using the RAMP function by the following equation:

\[ \alpha(\gamma)=\alpha_f+\left(\alpha_s-\alpha_f\right)\frac{1-\gamma}{1+q_f\gamma} \]

here, \(\alpha_f\)Resistance in the fluid domain,\(\alpha_s\)The resistance of the solid region,\(q_f\)This parameter adjusts the nonlinearity of the interpolation function.

The values ​​at both ends are as follows:

\[ \gamma=1\Longrightarrow\alpha(\gamma)=\alpha_f \]
\[ \gamma=0\Longrightarrow\alpha(\gamma)=\alpha_s \]

The resistance values ​​of the fluid side and the solid side are defined by the following equations, respectively.

\[ \alpha_f=\frac{5\mu}{2H_t^2} \]
\[ \alpha_s=\frac{5\mu}{2\left(H_t/100\right)^2} \]

here, \(\mu\)The viscosity coefficient of the fluid,\(H_t\)This represents half the thickness of the upper thermal fluid layer.

In the solid domain, a much larger resistance is applied than in the fluid domain, which affects the Brinkman resistance term included in the momentum conservation law.

\[ -\alpha(\gamma)\mathbf{u} \]

This reduces the flow velocity inside the walls and fins to almost zero. On the other hand,\(\gamma\simeq1\)In the flow path region, resistance decreases, allowing the fluid to flow.

Conversion from material distribution to thermal conductivity

material distribution \ (\ gamma \)This is the effective thermal conductivity of the upper thermal fluid layer. \(k_t(\gamma)\)This will also be reflected there.

\[ k_t(\gamma)=k_f+\left(k_s-k_f\right)\frac{1-\gamma}{1+q_k\gamma} \]

here, \(k_f\)The thermal conductivity of the fluid is\(k_s\)The thermal conductivity of a solid,\(q_k\)This parameter adjusts the nonlinearity of the interpolation function.

\[ \gamma=1\Longrightarrow k_t(\gamma)=k_f \]
\[ \gamma=0\Longrightarrow k_t(\gamma)=k_s \]

Therefore, the thermal conductivity of the fluid is used in the flow channel, while the thermal conductivity of the solid is used inside the walls and fins.

Intermediate parts that appear during optimization \ (\ gamma \) For this, the effective thermal conductivity between the fluid and the solid is given.

Conversion from material distribution to interlayer heat transfer coefficient

Heat transfer coefficient between the upper thermal fluid layer and the lower substrate layer \(h(\gamma)\)Also, effective thermal conductivity \(k_t(\gamma)\)It depends on the material distribution.

The heat transfer coefficient on the upper thermal fluid layer side is,

\[ h_t(\gamma)=\frac{35k_t(\gamma)}{26H_t} \]

The heat transfer coefficient on the lower substrate layer side is,

\[ h_b=\frac{k_b}{H_b}=\frac{k_s}{H_b} \]

It is represented as follows: Here,\(k_b\)The thermal conductivity of the substrate,\(H_b\)This represents half the thickness of the lower substrate layer.

The heat transfer coefficient of the upper and lower layers combined is calculated by connecting the thermal resistances of both layers in series.

\[ h(\gamma)=\frac{h_t(\gamma)h_b}{h_t(\gamma)+h_b} \]

This is how it is calculated.

Therefore, the shape of the MMC components changes. \ (\ gamma \)When this changes, not only the fluid resistance but also the thermal conductivity of the upper layer and the amount of heat transferred from the substrate to the upper layer change.

Based on the above, changes in the shape of the MMC components will be reflected in the thermal fluid analysis through the following pathway.

\[ \left\{X_0,Y_0,L,t,\theta,a,k,\psi\right\}\rightarrow\left\{\phi_w,\phi_f\right\}\rightarrow\left\{\widetilde{\phi}_w,\widetilde{\phi} _f\right\}\rightarrow\gamma\rightarrow\left\{\alpha(\gamma),k_t(\gamma),h(\gamma)\right\}\rightarrow\left\{\mathbf{u},p,T_t,T_b\right\} \]

In other words, when the position, dimensions, and angles of walls and fins are updated through optimization, their shape changes depending on the material distribution. \ (\ gamma \)This is converted, and the fluid resistance and thermophysical properties for each finite element are updated.

This allows changes in the shape of the components to be reflected in the flow field and temperature field without having to recreate the analysis mesh during optimization.

Optimization Problem

fillet


Liquid cooling plate to be optimized

The target of optimization is a liquid-cooled cooling plate, as shown in the diagram above.

The inlet is located in the upper left and the outlet in the lower left, and the fluid is driven by using the inlet and outlet as pressure boundaries.

For the fluid domain, we will use water for physical properties, and for the solid domain, we will use silicon for physical properties.

By applying a constant heat flow velocity across the entire design area, we simulate the presence of a heat-generating object.

\[ J=\left(\frac{1}{\left|\Omega_b\right|}\int_{\Omega_b}T_b(X,Y)^p\,d\Omega\right)^{1/p} \]

The objective function is given by the solid region temperature as shown in the above equation.\(P\)Using the norm mean,\(p=10\)Because it was set in this way, the objective function is equivalent to minimizing the maximum temperature.

Optimization Results

Optimization results of walls and fins at each inflow pressure.

In this study, the inflow pressure\(P_{in}= 50, 100, 200 Pa\) We optimized the wall and fin components for the three conditions described above.

Optimization of wall components

fillet


Optimization results for wall components: Inflow pressure 50 Pa

(a) \(P_{in}=50 Pa\)Results

fillet


Optimization results for wall components: Inflow pressure 100 Pa

(B) \(P_{in}=100 Pa\)Results

fillet


Optimization results for wall components: Inflow pressure 200 Pa

(C) \(P_{in}=200 Pa\)Results

The figure above shows the optimization process of the wall components at each inflow pressure. The top row of each condition shows the material distribution, the middle row shows the flow velocity distribution, and the bottom row shows the substrate temperature distribution.

In the initial configuration, the cooling fluid tends to flow directly from the inlet to the nearby outlet, resulting in insufficient flow reaching the right side of the design area.

As optimization progressed, the wall components moved and deformed to block this short-circuit flow at all inflow pressures, forming a global flow path that diverted the cooling fluid to the right side of the design region.

As a result, the cooling fluid passes through a wider area, lowering the temperature of the entire substrate.

fillet


Objective function history in wall component optimization

Looking at the objective function history in the figure above, we can see that for all inflow pressures, the objective function decreases significantly in the early stages of optimization, and then converges to a nearly constant value.

As the inflow pressure increases, the flow velocity increases, and heat transport by convection becomes stronger, resulting in a smaller final objective function.

Optimization of fin components

After optimizing the wall components, we removed the small wall components that did not contribute to the formation of the global flow path, and then optimized the fin components while fixing the remaining flow path shape.

fillet


Optimization results of fin components: Inflow pressure 50 Pa

(a) \(P_{in}=50 Pa\)Results

fillet


Optimization results of fin components: Inflow pressure 100 Pa

(B) \(P_{in}=100 Pa\)Results

fillet


Optimization results of fin components: Inflow pressure 200 Pa

(C) \(P_{in}=200 Pa\)Results

In the diagram above, the size and orientation of the fins change according to the local flow, forming a shape that guides the cooling fluid to the high-temperature region.

At all inflow pressures, the fin optimization locally tuned the flow, resulting in even better cooling performance compared to optimizing only the walls.

On the other hand, the number and distribution of fins remaining after optimization will vary depending on the inflow pressure.

When the inflow pressure is high, the flow bending and recirculation caused by the fins promotes fluid mixing and improves heat transfer by thinning the thermal boundary layer, so a relatively large number of fins remain.

In contrast, when the inflow pressure is low, heat transport by convection is weak, and the increase in flow resistance due to the fins becomes relatively larger, so the fins are arranged more sparsely.

fillet


Objective function history in fin component optimization

As can be seen in the figure above, the objective function has also been reduced.

Comparison with topology optimization based on density method

To evaluate the performance of the proposed method, inflow pressure \(P_{in}=200 Pa\)We compared these conditions with topology optimization based on a general density method.

For the comparison, the thermal-fluid model, boundary conditions, finite element mesh, interpolation method for material properties, and initial material distribution are common to both methods.

fillet


Results of topology optimization based on density method

While the proposed method uses the position, dimensions, and orientation of the walls and fins as design variables, the density method directly updates the density variables placed for each finite element.

Therefore, the density method offers a very high degree of freedom in terms of local shape, and the figure above shows a material distribution that includes numerous elongated shapes and complex local structures.

It should be noted that some of the rod-shaped and elliptical features observed in the results originate from the initial material distribution common to both methods, and the density method is not subject to any geometric constraints on walls or fins.

fillet


Comparison of objective function histories in the proposed method and density method.

Looking at the objective function history above, in the proposed method, the objective function rapidly decreases due to the initial wall optimization, shows a temporary fluctuation when switching between optimization stages, and then decreases further due to fin optimization.

On the other hand, in the density method, all density variables are updated continuously, so the objective function decreases relatively smoothly.

Ultimately, the proposed method achieved a value of approximately 319.48, while the density method achieved approximately 319.40, indicating that both methods achieved nearly equivalent cooling performance.

The number of design variables is 299 in the proposed method, compared to 84,480 in the density-based optimization method, meaning the proposed method optimizes with approximately 1/283 the number of design variables.

Despite significantly reducing local degrees of freedom by limiting the shape representation to walls and fins, the system achieved an objective function nearly equivalent to that obtained with density-based optimization, confirming the effectiveness of representing shapes using the components intended by the designer.

The important point of this comparison is not that the proposed method generally showed higher performance than the density method.

The significance of this approach lies in achieving a simpler, more interpretable, and dimensionally adjustable shape while maintaining comparable cooling performance, even with a more limited design space compared to density-based optimization.

Comparison with simultaneous optimization of walls and fins

To verify the effectiveness of the proposed two-stage optimization, inflow pressure \(P_{in}=200 Pa\) Under these conditions, we compared this with an optimization that updates both the wall and fin components simultaneously.

The initial shape, objective function, governing equations, boundary conditions, interpolation method for material properties, and finite element mesh are the same as those used in two-stage optimization.

fillet


Comparison of results between two-stage optimization and simultaneous wall/fin optimization.

In the simultaneous optimization shown in the diagram above, all design variables for the wall and fin are updated simultaneously.

As a result, some of the wall components, originally introduced to form global flow channels, are used to promote local heat transfer, while conversely, some of the fin components are involved in the formation of global flow channels.

Thus, the functions of the wall and the fin become intertwined, making it unclear what physical role each component plays in the final shape.

In contrast, two-stage optimization first determines the global flow channel structure using only wall components and fixes its shape, after which local flow and heat transfer are adjusted using only fin components.

Therefore, the pre-defined functional divisions—that "walls form global airflow channels" and "fins promote localized heat transfer"—are clearly reflected in the final shape.

fillet


Comparison of objective function histories in two-stage optimization and simultaneous optimization.

Looking at the objective function history above, simultaneous optimization updates the walls and fins at the same time, so the objective function degrades rapidly in the initial stages of optimization.

However, the decrease in the objective function slowed down after that, and the final value was approximately 320.46.

On the other hand, the two-stage optimization process, which involves switching from wall optimization to fin optimization, ultimately reduces the score to approximately 319.48.

Although the difference in the objective functions between the two methods is not significant, two-stage optimization achieves a lower objective function than simultaneous optimization while suppressing functional competition between components.

Furthermore, the resulting shapes have clear physical meanings, and because only the walls can be modified when changing the global flow path, and only the fins can be modified when adjusting local heat transfer, the results are also suitable for design adjustments after optimization.

Final thoughts

This article explains the research papers that were accepted for publication in the international academic journal Structural and Multidisciplinary Optimization (SMO).

Specifically, the paper targeted the topology optimization of cooling channels, defining components assigned different physical roles: "walls" that form global channels and "fins" that promote local heat transfer. By dividing the optimization process according to each role, the paper proposed a two-stage optimization method that allows for design while suppressing competition between the two.

In this study, the solid domain was represented using MMC components, but as shown in previous research [7], representing the fluid domain with MMC is also a valid option, allowing for flexible extensions depending on the purpose and constraints.

The proposed optimization framework is merely an example; it is crucial to determine the appropriate components and constraints/roles to be assigned according to the actual design challenge, and then construct the optimal framework.

At our company, we build optimal frameworks tailored to individual design challenges, enabling designers to appropriately interpret and utilize the optimization results, thereby achieving competitive, high-performance product designs.

References

[1] Hirotani, S., Shintani, K., Furusawa, Y., and Yaji, K. “Topology optimization of cooling channels using dual-type moving morphable components.” Structural and Multidisciplinary Optimization Vol. 69, No. 186, 2026.

[2] Bendsøe, MP, and Kikuchi, N., “Generating Optimal Topologies in Structural Design Using a Homogenization Method,” Computer Methods in Applied Mechanics and Engineering, Vol. 71, No. 2, 1988, pp. 197–224.

[3] Bendsøe, MP, “Optimal Shape Design as a Material Distribution Problem,” Structural Optimization, Vol. 1, No. 4, 1989, pp. 193–202.

[4] Guo, X., Zhang, WS, and Zhong, WL, “Doing Topology Optimization Explicitly and Geometrically-A New Moving Morphable Components Based Framework,” Journal of Applied Mechanics, Vol. 81, No. 8, 2014, p. 081009.

[5] Hirotani S, Yaji K, Makihara K, and Otsuka K., “Data-driven real-time topology optimization using consistent rotation-based moving morphable components.” AIAA J, Vol. 63, No. 10, 2025, pp. 4491-4497.

[6] Yan, S., Wang, F., Hong, J., and Sigmund, O., “Topology optimization of microchannel heat sinks using a two-layer model.” International Journal of Heat and Mass TransferVol. 143, 2019, 118462.

[7] Yu, M., Ruan, S., Wang, X., Li, Z., and Shen, C., “Topology optimization of thermal-fluid problem using the MMC-based approach,” Structural and Multidisciplinary Optimization, Vol. 60, 2019, pp. 151-165.

A paper co-authored by Shunsuke Hirotani, Kunitaka Shintani, and Yoshikatsu Furusawa of our company, together with Associate Professor Kentaro Yaji of the Graduate School of Engineering, The University of Osaka, has been accepted for publication in the international academic journal Structural and Multidisciplinary Optimization (SMO) [1]. In this article, we aim to provide an accessible explanation of the key ideas and concepts behind the research.

Introduction

Topology optimization can reveal design possibilities that human designers may not readily conceive, making it a powerful tool for developing better-performing products [2].

Among the various topology optimization approaches, density-based topology optimization is widely used and has been applied not only to structural problems but also to thermofluid systems and many other fields [3].

fillet


Example of density-based topology optimization applied to a cooling channel

However, topology optimization often produces highly complex geometries, which can make the resulting designs difficult to physically interpret, translate into manufacturable products, and control in terms of manufacturing quality.

Although filters can be used in density-based topology optimization to control member dimensions indirectly, it remains difficult to impose complex design constraints strictly on the optimized geometry.

To obtain practical design solutions based on existing manufacturing technologies, designers must interpret the optimization results and perform post-processing to convert them into manufacturable geometries while taking great care not to compromise optimality.

Post-processing is also essential when converting optimization results into CAD models, because grayscale density distributions must be transformed into clear, well-defined geometries.

In this study, we proposed a topology optimization method for cooling channels that can flexibly incorporate geometric design constraints, such as dimensional limits, while producing results that are physically interpretable and readily adjustable after optimization.

Moving Morphable Components (MMC)

Moving Morphable Components (MMC) is one approach to topology optimization [4].

fillet


Conceptual illustration of Moving Morphable Components (MMC)

In the MMC approach, geometric entities that can potentially placed become members of the optimized design are in the design domain as “components,” independently of the finite elements used for analysis. The geometry is then represented through the translation, rotation, enlargement, reduction, and overlap of these components.

For an overview of the MMC formulation and examples applied to structural benchmark problems, please refer to our previous article.

Overview and Comparison of Topology Optimization Methods | Nature Architects Inc.

Because MMC directly treats geometric information, such as component dimensions, positions, and orientations, as design variables, it can strictly incorporate geometric constraints into the optimization problem, including requirements such as:

  • “The thickness of this member must remain within a specified range.”
  • “This component may move only within a specified region.”
  • “Adjacent components must maintain C¹ continuity [5].”

Furthermore, because the design variables are the geometric parameters themselves, the optimized result can be transferred seamlessly to a CAD system, providing an important practical advantage.

Overview of the Proposed Cooling-Channel Optimization Framework

In this study, we defined two types of components with different physical roles: “walls,” which form the global flow-path network, and “fins,” which promote local heat transfer. We then proposed a two-stage optimization method that separates the optimization stages according to these roles, thereby suppressing functional competition between the two component types. The concept of the method is illustrated below.

fillet


Conceptual illustration of the proposed two-stage optimization method

  1. Step: 1 Place wall components and fin components within the design domain.
  2. Step: 2 Optimize the global flow-path network using only the wall components as design variables.
  3. Step: 3 Remove wall components whose dimensions fall below a prescribed threshold and that therefore do not contribute to forming the global flow path.
  4. Step: 4 Remove fin components located closer than a prescribed threshold distance to the retained wall components, leaving only the fin candidates used in the second optimization stage.
  5. Step: 5 Optimize the local heat-transfer characteristics within the flow channel using only the retained fin components as design variables.
  6. Step: 6 Finally, remove fin components whose dimensions fall below a prescribed threshold and adopt the resulting structure as the final design.

The detailed optimization procedure consists of Steps 1 through 6 described above.

By separating the optimization stages according to physical roles and pruning components that do not serve the intended function between stages, the method can produce manufacturable results that remain consistent with the designer's intent.

Thermofluid Analysis Model

This study employs a two-layer thermofluid model consisting of an upper thermofluid layer, which contains the coolant and channel walls, and a lower substrate layer, which receives heat from the heat-generating body [6].

By assuming velocity and temperature distributions in the thickness direction, the inherently three-dimensional flow and heat-transfer problem is reduced to a two-dimensional problem. This enables the large number of analyzes required for topology optimization to be performed efficiently.

In the upper thermofluid layer, the fluid is assumed to be incompressible, and the continuity equation is solved:

\[ \nabla \cdot \mathbf{u}=0 \]

Here, \(\mathbf{u}\) This is the in-plane velocity.

The following momentum conservation equation is used, including a Brinkman resistance term that suppresses flow inside the solid region:

\[ \frac{6}{7}\rho\left(\mathbf{u}\cdot\nabla\right)\mathbf{u}=-\nabla p+\mu\nabla\cdot\left[\nabla\mathbf{u}+\left(\nabla\mathbf{u}\right)^{\mathrm{T}}\right]-\alpha(\gamma)\mathbf{u} \]

The final term on the right-hand side, \(-\alpha(\gamma)\mathbf{u}\), is the Brinkman resistance.

By assigning a small resistance in the fluid region and a large resistance in the solid region, the flow channel and the channel walls can be represented within the same governing equation.

For the temperature \(T_t\) in the upper thermofluid layer, the model considers heat transport by fluid flow, in-plane thermal conduction, and heat exchange with the lower substrate layer:

\[ \frac{2}{3}\rho C_p\mathbf{u}\cdot\nabla T_t-\frac{49}{52}\nabla\cdot\left(k_t(\gamma)\nabla T_t\right)-\frac{h(\gamma)}{2H_t}\left(T_b-T_t\right)=0 \]

The first term represents heat advection by the fluid, the second represents thermal conduction, and the third represents heat transfer between the upper thermofluid layer and the lower substrate layer.

In the lower substrate layer, fluid flow is neglected, and heat conduction within the substrate is calculated using:

\[ -\frac{k_b}{2}\nabla^2 T_b+\frac{h(\gamma)}{2H_b}\left(T_b-T_t\right)-\frac{q_0^{\prime\prime}}{2H_b}=0 \]

Here, \(T_b\) is the representative temperature of the substrate layer, and \(q_0^{\prime\prime}\) is the heat flux supplied by the heat-generating body.

Heat introduced from the heat-generating body into the substrate is conducted through the substrate and then transferred to the fluid or the channel walls in the upper layer.

Mathematical Representation of MMC Components and Their Incorporation into Material Properties

In MMC, walls and fins are represented as explicit geometric components, and their positions, dimensions, and orientations are as design variables. In the thermofluid analysis, however, it is necessary to represent whether each location on a fixed finite-element mesh corresponds to fluid or solid using a material distribution field \ (\ gamma \).

In this study, the shapes of the MMC components are therefore incorporated into the material properties used in the thermofluid analysis through the following sequence:

\[ \text{Design variables of MMC components}\rightarrow\text{Topology Description Function (TDF)}\rightarrow\text{Projected TDF}\rightarrow\gamma\rightarrow\left\{\alpha(\gamma),\ k_t(\gamma),\ h(\gamma)\right\} \]

Here, \(\alpha(\gamma)\) is the flow resistance. \(k_t(\gamma)\) is the effective thermal conductivity of the upper thermofluid layer, and \(h(\gamma)\) is the heat-transfer coefficient between the two layers.

TDF of a Wall Component

Let an arbitrary point in the design domain be \((X,Y)\), and let the center coordinates of a wall component be \((X_0,Y_0)\). First, local coordinates aligned with the orientation of the wall component are defined as follows:

\[ \Delta X_w=X-X_0,\qquad \Delta Y_w=Y-Y_0 \]
\[ s_w=\Delta X_w\cos\theta+\Delta Y_w\sin\theta \]
\[ n_w=\Delta X_w\sin\theta+\Delta Y_w\cos\theta \]

Here, \(s_w\) is the local coordinate along the longitudinal direction of the wall, \(n_w\) is the local coordinate normal to that direction, and \(\theta\) is the rotation angle of the wall component.

The geometry of the wall component is represented by the following sixth-order superelliptic TDF:

\[ \phi_w(X,Y)=1-\left(\frac{s_w}{L}\right)^6\left(\frac{n_w}{t}\right)^6 \]

Here, \(L\) is the longitudinal dimension, and \(t\) is the transverse dimension.

Using an exponent of six provides a smooth representation of a bar-like wall geometry that is more rectangular than an ordinary ellipse.

TDF of a Fin Component

Similarly, local coordinates are defined for a fin component whose center coordinates are \((X_f,Y_f)\):

\[ \Delta X_f=X-X_f,\qquad \Delta Y_f=Y-Y_f \]
\[ s_f=\Delta X_f\cos\psi+\Delta Y_f\sin\psi \]
\[ n_f=\Delta X_f\sin\psi+\Delta Y_f\cos\psi \]

Here, \(\psi\) is the rotation angle of the fin.

An elliptical fin component is represented by the following TDF:

\[ \phi_f(X,Y)=1-\left(\frac{s_f}{a}\right)^2\left(\frac{n_f}{ka}\right)^2 \]

\(The\) is the major radius of the ellipse, and \(to\) is the ratio of the minor radius to the major radius. \(B\) is therefore:

\[ b=ka \]

Thus, the fin is circular when \(k=1\), while decreasing \(to\) produces a more slender ellipse.

Note that \(to\) here denotes the aspect ratio of the fin geometry and is distinct from the thermal conductivities \(k_f\) and \(k_s\) Introduction several times.

For both wall and fin components, the TDF has the following sign convention:

\[ \phi>0\quad\text{: inside the component} \]
\[ \phi=0\quad\text{: on the component boundary} \]
\[ \phi<0\quad\text{: outside the component} \]

Conversion from the TDF to the Material Distribution

Because the TDF cannot be used directly as a material distribution ranging from 0 to 1, each TDF is approximately projected onto the interval from 0 to 1 using a hyperbolic tangent function.

The projected TDF of a wall component is:

\[ \widetilde{\phi}_w(X,Y)=\frac{1}{2}\left[1-\tanh\left(\beta\phi_w(X,Y)\right)\right] \]

The projected TDF of a fin component is:

\[ \widetilde{\phi}_f(X,Y)=\frac{1}{2}\left[1-\tanh\left(\beta\phi_f(X,Y)\right)\right] \]

The parameters \(\beta\) controls the sharpness of the transition between fluid and solid at a component boundary. Under this definition, the projected TDF approaches 0 inside a component and 1 outside it.

\[ \text{Inside a component: }\phi>0\Longrightarrow\widetilde{\phi}\simeq0 \]
\[ \text{Outside a component: }\phi<0\Longrightarrow\widetilde{\phi}\simeq1 \]

Rather than multiplying the raw TDFs of the walls and fins directly, the material distribution \ (\ gamma \) is obtained from the product of these projected functions.

Combined Material Distribution of Walls and Fins

Let \(C_w\) denote the set of wall components and \(C_f\) the set of fin components. The material distribution over the entire design domain is then expressed as:

\[ \gamma(X,Y;\mathbf{d})=\left[\prod_{m\in C_w}\widetilde{\phi}_{w,m}(X,Y;\mathbf{d}_{w,m})\right]\left[\prod_{n\in C_f}\widetilde{\phi}_{f,n}(X,Y;\mathbf{d}_{f,n})\right] \]

Here, \(\mathbf{d}_{w,m}\) and \(\mathbf{d}_{f,n}\) are the design variables of the wall and fin components, respectively.

The material distribution in this study is defined by:

\[ 0\leq\gamma\leq1 \]
\[ \gamma\simeq0\quad\text{: solid region} \]
\[ \gamma\simeq1\quad\text{: fluid region} \]

Because the projected TDFs are multiplied, if a point lies inside any wall or fin component, the value of \ (\ gamma \) at that point approaches 0 and the point is treated as solid.

offline, at a point outside all components, each projected TDF approaches 1, so \ (\ gamma \) also approaches 1 and the point is treated as fluid.

Thus, this product represents the union of the solid regions formed by multiple wall and fin components. Regions where walls and fins overlap are also treated as solid.

In the two-stage optimization, only the set of design variables being updated changes; the material-distribution representation itself remains common to both the first and second stages.

Conversion from the Material Distribution to Flow Resistance

The material distribution \ (\ gamma \) is first incorporated into the Brinkman resistance coefficient \(\alpha(\gamma)\). The resistance between the fluid and solid phases is interpolated using the following RAMP function:

\[ \alpha(\gamma)=\alpha_f+\left(\alpha_s-\alpha_f\right)\frac{1-\gamma}{1+q_f\gamma} \]

Here, \(\alpha_f\) is the resistance in the fluid region, \(\alpha_s\) is the resistance in the solid region, and \(q_f\) controls the nonlinearity of the interpolation function.

The values ​​at the two endpoints are:

\[ \gamma=1\Longrightarrow\alpha(\gamma)=\alpha_f \]
\[ \gamma=0\Longrightarrow\alpha(\gamma)=\alpha_s \]

The resistance values ​​on the fluid and solid sides are defined as:

\[ \alpha_f=\frac{5\mu}{2H_t^2} \]
\[ \alpha_s=\frac{5\mu}{2\left(H_t/100\right)^2} \]

Here, \(\mu\) is the dynamic viscosity of the fluid, and \(H_t\) is the half-thickness of the upper thermofluid layer.

By assigning a much larger resistance to the solid region than to the fluid region, the Brinkman resistance term in the momentum conservation equation,

\[ -\alpha(\gamma)\mathbf{u} \]

reduces the velocity inside the walls and fins to nearly zero. In contrast, the resistance is small in the flow-channel region where \(\gamma\simeq1\), allowing the fluid to flow.

Conversion from the Material Distribution to Thermal Conductivity

The material distribution \ (\ gamma \) is also incorporated into the effective thermal conductivity \(k_t(\gamma)\) of the upper thermofluid layer:

\[ k_t(\gamma)=k_f+\left(k_s-k_f\right)\frac{1-\gamma}{1+q_k\gamma} \]

Here, \(k_f\) is the thermal conductivity of the fluid, \(k_s\) is the thermal conductivity of the solid, and \(q_k\) controls the nonlinearity of the interpolation function.

\[ \gamma=1\Longrightarrow k_t(\gamma)=k_f \]
\[ \gamma=0\Longrightarrow k_t(\gamma)=k_s \]

Accordingly, the thermal conductivity of the fluid is used in the flow-channel region, while the thermal conductivity of the solid is used inside the walls and fins.

For intermediate to of \ (\ gamma \) that appears during optimization, an effective thermal conductivity between the fluid and solid values ​​is assigned.

Conversion from the Material Distribution to the Interlayer Heat-Transfer Coefficient

The heat-transfer coefficient \(h(\gamma)\) between the upper thermofluid layer and the lower substrate layer also depends on the material distribution through the effective thermal conductivity \(k_t(\gamma)\).

The heat-transfer coefficient on the upper thermofluid-layer side is:

\[ h_t(\gamma)=\frac{35k_t(\gamma)}{26H_t} \]

The heat-transfer coefficient on the lower substrate-layer side is:

\[ h_b=\frac{k_b}{H_b}=\frac{k_s}{H_b} \]

Here, \(k_b\) is the thermal conductivity of the substrate, and \(H_b\) is the half-thickness of the lower substrate layer.

The combined heat-transfer coefficient of the two layers is calculated by treating their thermal resistances as being connected in series:

\[ h(\gamma)=\frac{h_t(\gamma)h_b}{h_t(\gamma)+h_b} \]

tested, when the shape of an MMC component changes and \ (\ gamma \) is updated, not only the flow resistance but also the thermal conductivity of the upper layer and the amount of heat transferred from the substrate to the upper layer change.

In summary, a change in the geometry of an MMC component is reflected in the thermofluid analysis through the following sequence:

\[ \left\{X_0,Y_0,L,t,\theta,a,k,\psi\right\}\rightarrow\left\{\phi_w,\phi_f\right\}\rightarrow\left\{\widetilde{\phi}_w,\widetilde{\phi} _f\right\}\rightarrow\gamma\rightarrow\left\{\alpha(\gamma),k_t(\gamma),h(\gamma)\right\}\rightarrow\left\{\mathbf{u},p,T_t,T_b\right\} \]

In other words, when optimization updates the positions, dimensions, and orientations of the walls and fins, their geometries are converted into the material distribution \ (\ gamma \), and the flow resistance and thermal properties of each finite element are updated accordingly.

This allows geometric changes in the components to be reflected in the flow and temperature fields without remeshing the analysis domain during optimization.

Optimization Problem

fillet


Liquid-cooled cold plate considered in the optimization problem

The optimization target is a liquid-cooled cold plate of the type shown above.

The inlet is located at the upper left and the outlet at the lower left. The fluid is driven by prescribing pressure boundary conditions at the inlet and outlet.

Water is used for the material properties of the fluid region, and silicon is used for those of the solid region.

A heat-generating body is modeled by applying a uniform heat flux over the entire design domain.

\[ J=\left(\frac{1}{\left|\Omega_b\right|}\int_{\Omega_b}T_b(X,Y)^p\,d\Omega\right)^{1/p} \]

The objective function is the \(P\)-norm mean of the solid-region temperature shown above. \(p=10\) is used, the objective is approximately equivalent to minimizing the maximum temperature.

Optimization Results

Optimized Wall and Fin Configurations at Different Inlet Pressures

In this study, the wall and fin components were optimized under three inlet-pressure conditions: \(P_{in}=50,\ 100,\text{ and }200\ \mathrm{Pa}\).

Optimization of the Wall Components

fillet


Optimization result for the wall components at an inlet pressure of 50 Pa

(a) Result for \(P_{in}=50\ \mathrm{Pa}\)

fillet


Optimization result for the wall components at an inlet pressure of 100 Pa

(b) Result for \(P_{in}=100\ \mathrm{Pa}\)

fillet


Optimization result for the wall components at an inlet pressure of 200 Pa

(c) Result for \(P_{in}=200\ \mathrm{Pa}\)

The figures above show the optimization process for the wall components at each inlet pressure. For each condition, the upper row shows the material distribution, the middle row shows the velocity distribution, and the lower row shows the substrate temperature distribution.

In the initial design, the coolant trends to flow directly from the inlet to the nearby outlet, preventing sufficient flow from reaching the right side of the design domain.

As optimization proceeds, the wall components move and deform so as to block this short-circuit flow under all inlet-pressure conditions, forming a global flow path that redirects the coolant toward the right side of the design domain.

As a result, the coolant passes through a wider portion of the domain, reducing the temperature throughout the substrate.

fillet


Objective-function history during optimization of the wall components

The objective-function history shows a substantial decrease during the early stage of optimization for every inlet pressure, followed by convergence to an almost constant value.

A higher inlet pressure produces a higher flow velocity and therefore stronger convective heat transport, resulting in a lower final objective-function value.

Optimization of the Fin Components

After optimizing the wall components, small wall components that did not contribute to forming the global flow path were removed. The remaining flow-path geometry was then fixed, and the fin components were optimized.

fillet


Optimization result for the fin components at an inlet pressure of 50 Pa

(a) Result for \(P_{in}=50\ \mathrm{Pa}\)

fillet


Optimization result for the fin components at an inlet pressure of 100 Pa

(b) Result for \(P_{in}=100\ \mathrm{Pa}\)

fillet


Optimization result for the fin components at an inlet pressure of 200 Pa

(c) Result for \(P_{in}=200\ \mathrm{Pa}\)

The figures above show that the sizes and orientations of the fins change in response to the local flow, forming geometries that guide the coolant toward high-temperature regions.

At every inlet pressure, optimizing the fins locally adjusts the flow and further improves cooling performance relative to the design obtained by optimizing only the walls.

However, the number and distribution of the fins remaining after optimization depend on the inlet pressure.

At higher inlet pressures, flow turning and recirculation induced by the fins promote fluid mixing and enhance heat transfer by thinning the thermal boundary layer. examined, a relatively large number of fins remain.

At relatively lower inlet pressures, convective heat transport is weaker, and the increase in flow resistance caused by the fins becomes more significant. The optimized fins are therefore distributed more sparsely.

fillet


Objective-function history during optimization of the fin components

As shown above, the objective function is further reduced by optimizing the fins.

Comparison with Density-Based Topology Optimization

To evaluate the performance of the proposed method, a comparison was performed with conventional density-based topology optimization under the inlet-pressure condition \(P_{in}=200\ \mathrm{Pa}\).

The thermofluid model, boundary conditions, finite-element mesh, material-property interpolation method, and initial material distribution were identical for the two methods.

fillet


Result obtained using density-based topology optimization

Additionally, the proposed method uses the positions, dimensions, and orientations of the walls and fins as design variables, the density-based method directly updates density variables assigned to individual finite elements.

The density-based method therefore has very high local geometric freedom, and the result shown above contains many slender features and complex local structures.

Some of the bar-like and elliptical features remaining in the result originate from the initial material distribution shared by both methods; the density-based method itself was not subject to geometric constraints associated with walls or fins.

fillet


Comparison of the objective-function histories for the proposed method and the density-based method

The objective-function histories show that, in the proposed method, the objective decreases rapidly during the initial wall-optimization stage, exhibits a temporary variation when the optimization stage is switched, and then decreases further during fin optimization.

In contrast, the density-based method continuously updates all density variables, resulting in a comparatively smooth decrease in the objective function.

The final objective-function values ​​were approximately 319.48 for the proposed method and 319.40 for the density-based method, indicating that the two methods achieved nearly equivalent cooling performance.

The proposed method used 299 design variables, whereas the density-based optimization used 84,480. Thus, the proposed method performed the optimization with approximately 1/283 as many design variables.

Although the local degrees of freedom were greatly reduced by restricting the geometric representation to walls and fins, the proposed method achieved almost the same objective-function value as the density-based method. This result demonstrates the effectiveness of representing the geometry using components whose roles are intentionally defined by the designer.

The important point of this comparison is not that the proposed method generally outperforms the density-based method.

Rather, its significance lies in obtaining a simpler, more interpretable geometry that is easier to modify dimensionally while maintaining cooling performance to comparable that of density-based optimization, despite operating in a more restricted design space.

Comparison with Simultaneous Optimization of Walls and Fins

To examine the effectiveness of the proposed two-stage optimization, it was compared with an approach that simultaneously updates the wall and fin components under the inlet-pressure condition \(P_{in}=200\ \mathrm{Pa}\).

The initial geometry, objective function, governing equations, boundary conditions, material-property interpolation method, and finite-element mesh were identical to those used in the two-stage optimization.

fillet


Comparison between the two-stage optimization and simultaneous wall-and-fin optimization

In the simultaneous optimization shown above, all design variables of the walls and fins are updated at the same time.

As a result, some wall components originally introduced to form the global flow path are instead used to promote local heat transfer, while some fin components become involved in forming the global flow path.

The functions of the walls and fins therefore become mixed, making the physical role of each component in the final geometry unclear.

In the two-stage optimization, by contrast, the skeleton of the global flow path is first determined using only the wall components. After that geometry is fixed, only the fin components are used to adjust the local flow and heat transfer.

examined, the functional intended division—walls for global flow-path formation and fins for local heat-transfer enhancement—remains clearly visible in the final geometry.

fillet


Comparison of the objective-function histories for the two-stage and simultaneous optimization methods

The objective-function histories show that simultaneous optimization reduces the objective rapidly during the early stage because the walls and fins are updated together.

However, the subsequent decrease becomes more gradual, and the final value is approximately 320.46.

The two-stage optimization, in contrast, proceeds from wall optimization to fin optimization and ultimately reaches a value of approximately 319.48.

Although the difference between the two final objective-function values ​​is not large, the two-stage optimization suppresses functional competition between the component types while achieving a lower objective value than simultaneous optimization.

Furthermore, because the physical meaning of the resulting geometry is clear, post-optimization design adjustments can be made by modifying only the walls when changing the global flow path or only the fins when tuning local heat transfer.

Conclusion

This article introduced our research that was accepted for publication in the international journal Structural and Multidisciplinary Optimization (SMO).

The study addressed topology optimization of cooling channels and proposed a two-stage optimization method. Components assigned different physical roles—walls that form the global flow path and fins that promote local heat transfer—are optimized in separate stages to suppress competition between their functions.

Although the solid region was represented using MMC components in this study, representing the fluid region using MMC is also a viable option, as demonstrated in a previous study [7], and the framework can be extended flexibly according to the objective and constraints.

The proposed optimization framework is only one example. For an actual design problem, it is important to select appropriate components, constraints, and physical roles according to the specific requirements and to construct a suitable optimization framework.

At Nature Architects, we develop optimization frameworks tailored to individual design problems and enable the design of competitive, high-performance products by helping designers interpret and utilize optimization results appropriately.

References

[1] Hirotani, S., Shintani, K., Furusawa, Y., and Yaji, K., “Topology optimization of cooling channels using dual-type moving morphable components.” Structural and Multidisciplinary Optimization, Vol. 69, No. 186, 2026.

[2] Bendsøe, MP, and Kikuchi, N., “Generating Optimal Topologies in Structural Design Using a Homogenization Method,” Computer Methods in Applied Mechanics and Engineering, Vol. 71, No. 2, 1988, pp. 197–224.

[3] Bendsøe, MP, “Optimal Shape Design as a Material Distribution Problem,” Structural Optimization, Vol. 1, No. 4, 1989, pp. 193–202.

[4] Guo, X., Zhang, WS, and Zhong, WL, “Doing Topology Optimization Explicitly and Geometrically—A New Moving Morphable Components Based Framework,” Journal of Applied Mechanics, Vol. 81, No. 8, 2014, p. 081009.

[5] Hirotani, S., Yaji, K., Makihara, K., and Otsuka, K., “Data-driven real-time topology optimization using consistent rotation-based moving morphable components.” AIAA Journal, Vol. 63, No. 10, 2025, pp. 4491–4497.

[6] Yan, S., Wang, F., Hong, J., and Sigmund, O., “Topology optimization of microchannel heat sinks using a two-layer model.” International Journal of Heat and Mass TransferVol. 143, 2019, 118462.

[7] Yu, M., Ruan, S., Wang, X., Li, Z., and Shen, C., “Topology optimization of thermal-fluid problem using the MMC-based approach,” Structural and Multidisciplinary Optimization, Vol. 60, 2019, pp. 151–165.

Author